日韩色美女加勒比,麻豆一区在线观看,久久精品在,国产日韩骚逼av,老司机综合网,久色亚洲在线,欧美福利在线视频,91午夜福利国产,绿岛久久影院

Company main products: pump valve     Tel:0550-7031888
RSS|Shopping Cart|Mobile Version|Chinese|English
ANHUI TIANMA PUMP VALVE GROUP CO.,LTD OF CHINA
免費(fèi)服務(wù)熱線

400-889-9558

13605505188 、18098329999

Popular Keywords:
Contact / Contact
  • ANHUI TIANMA PUMP VALVE GROUP CO.,LTD OF CHINA
  • Tel:0550-7031888
  • Fax:0550-7321688
  • Email:sales@ahtmbv.com
  • Address:NO. 1 TIANMA ROAD ECNOMIC DEVELOPMENT ZONE OF TIANCHANG, ANHUI, CHINA
Technical
Function and selection of centrifugal pump's outlet che

     The role of the outlet valve is to prevent the flow of liquid in the outlet pipe to form a water hammer caused by pump impeller damage.
     Check valve installation and the number of the pump has nothing to do, check valve is mainly in order to stop the operation of the pump, to prevent the liquid return, so that the pump back, causing damage to the accident, and in order to prevent backflow of liquid
     Damage to other storage tanks (from the top of the tank can cause the tank to fill up).
     If you can ensure that the first close the exit valve before the pump, and the outlet valve leakage or damage.
1 type selection of the pump outlet check valve
     General pumping station project, the selection of the pump outlet check valve, should follow the following principles;
     The pipeline of the pump outlet pipe smaller diameter, DN is less than or equal to 50mm, should use the lift check valve.
     On the pump outlet pipe diameter DN 50mm pipe line, should be used to swing check valve swing check valve can be horizontal or vertical installation. Swing type check valve to rotate the rotating shaft of the rotating shaft, and the fluid
     Resistance is generally less than the lift check valve, which applies to the larger diameter of the occasion, the installation location is not restricted, usually installed in horizontal pipe, it is suitable for large caliber occasions. According to the number of valve flap can be divided
     For single swing, double disc swing and multi disc swing three. Single swing check valve in general use and medium caliber occasions. Large diameter pipeline with single swing check valve, in order to reduce the water hammer pressure
     Force, the best use can reduce the water hammer pressure relief valve. Double valve swing check valve suitable for large and medium diameter pipe. On the double valve swing check valve structure is small, light weight, is a quick check valve
; multi valve swing check valve is suitable for large diameter pipeline.
2 installation of pump outlet check valve
     The swing check valve is generally installed on the horizontal pipe: the check valve for the diameter of DN~80mm can also be installed in vertical or upward inclined pipe.
     The straight through lift check valve should be installed in horizontal pipe; vertical lift check valve must be installed in the vertical pipe, medium is from the bottom up.
As the check valve is easy to damage, therefore, should be close to the pump outlet to install check valve, in the upper part of the check valve (usually with ball valve or gate valve), convenient maintenance.
     (4) are easy to check back valve before the demolition relief, in check valve itself, without a net valve, check valve and shut-off valve installed between the pressure relief with a net release valve in.
3 protection measures against the sealing cover of the check valve by preventing hydraulic impact
     The setting of the check valve has the function of preventing the backflow of the material and avoiding the fluid hammer of the pump impeller. But on the check valve itself, set up properly, will cause water hammer generated by the valve seat of the valve
Impact, damage and check valve cover. Therefore, we should take some protective measures.
     1, for the pump set >80mm of the swing check valve, should be used to install the way, in order to reduce the valve flap back seat and impact.
     2, for the pump outlet check valve diameter >=150mm pipeline, should be in the check valve before and after the bypass valve to prevent the valve before the pressure rise is too high, the valve sealing surface damage caused by.
     3, the starting point and the end point of the pump discharge pipe line, do not allow to set the bypass, can take the following measures.
     Set the safety valve to replace the bypass valve. Its role is similar to the bypass valve. It is set near the exit of the check valve, when the water hammer pressure increases, a portion of the water can be released to prevent the pressure to continue to increase.
Into damage
     Air or inert gas buffer tank. Put it near the exit of the check valve, when the water hammer is generated, the pressure gas is compressed through the buffer tank to ease the pressure rise caused by the water hammer.

Return To The Top
  • 點(diǎn)擊這里給我發(fā)消息
  • 點(diǎn)擊這里給我發(fā)消息
  • 點(diǎn)擊這里給我發(fā)消息
  • 點(diǎn)擊這里給我發(fā)消息
  • 點(diǎn)擊這里給我發(fā)消息
高阳县| 皮山县| 城口县| 灌云县| 长阳| 周宁县| 岳阳市| 通海县| 治多县| 四平市| 大化| 余姚市| 宝山区| 苗栗县| 都昌县| 淮滨县| 沂南县| 扎囊县| 平凉市| 宣武区| 保德县| 温州市| 湄潭县| 永寿县| 墨竹工卡县| 云林县| 枝江市| 江安县| 洪雅县| 永州市| 武冈市| 佛坪县| 尉犁县| 广饶县| 湟源县| 武胜县| 蛟河市| 林西县| 清河县| 大连市| 饶阳县|